Inpatient
The study evaluates the diagnostic significance of QRS voltage variability (Shora sign) in identifying atrial fibrillation (AF) compared to conventional ECG criteria. It involves a case-control design with 200 AF…
Read MoreChecklists: UW Health Nursing One Pager – Electrophysiology Procedure Site Preparation
Read MoreEducation – Clinical: High level, informational video to share with general care physicians and emergency medicine providers that explains the benefits of referring AFib patients to an electrophysiologist.
Read MoreChecklists: Checklist to use when discharging and AFib patient same day.
Read MoreOrder Sets: ED AF <48h Protocol
Read MoreOrder Sets: ED AF >48h/Unknown Duration Protocol
Read MoreJournal Articles: BACKGROUND Multiple smart devices capable to detect atrial fibrillation (AF) are presently available. Sensitivity and specificity for the detection of AF may differ between available smart devices, and this has not yet been adequately investigated. OBJECTIVES The aim was to assess the accuracy of 5 smart devices in identifying AF compared with a physician interpreted 12-lead electrocardiogram as the reference standard in a real-world cohort of patients. METHODS We consecutively enrolled patients presenting to a cardiology service at a tertiary referral center in a prospective, diagnostic study. RESULTS We prospectively analyzed 201 patients (31% women, median age 66.7 years). AF was present in 62 (31%) patients. Sensitivity and specificity for the detection of AF were comparable between devices: 85% and 75% for the Apple Watch 6, 85% and 75% for the Samsung Galaxy Watch 3, 58% and 75% for the Withings Scanwatch, 66% and 79% for the Fitbit Sense, and 79% and 69% for the AliveCor KardiaMobile, respectively. The rate of inconclusive tracings (the algorithm was unable to determine the heart rhythm) was 18%, 17%, 24%, 21%, and 26% for the Apple Watch 6, Samsung Galaxy Watch 3, Withings Scan Watch, Fitbit Sense, and AliveCor KardiaMobile (P < 0.01 for pairwise comparison), respectively. By manual review of inconclusive tracings, the rhythm could be determined in 955 (99%) of 969 single-lead electrocardiograms. Regarding patient acceptance, the Apple Watch was ranked first (39% of participants). CONCLUSIONS In this clinical validation of 5 direct-to-consumer smart devices, we found differences in the amount of inconclusive tracings diminishing sensitivity and specificity of the smart devices. In a clinical setting, manual review of tracings is required in about one-fourth of cases.
Read MoreJournal Articles: OBJECTIVES This study compared the efficacy and safety of the VASCADE MVP Venous Vascular Closure System (VVCS) device (Cardiva Medical, Santa Clara, California) to manual compression (MC) for closing multiple access sites after catheter-based electrophysiology procedures. BACKGROUND The The VASCADE MVP VVCS is designed to provide earlier ambulatory hemostasis than MC after catheter-based procedures. METHODS The AMBULATE (A Randomized, Multi-center Trial to Compare Cardiva Mid-Bore (VASCADE MVP) VVCS to Manual Compression in Closure of Multiple Femoral Venous Access Sites in 6 – 12 Fr Sheath Sizes) trial was a multicenter, randomized trial of device closure versus MC in patients who underwent ablation. Outcomes included time to ambulation (TTA), total post-procedure time (TPPT), time to discharge eligibility (TTDe), time to hemostasis (TTH), 30-day major and minor complications, pain medication usage, and patient-reported outcomes. RESULTS A total of 204 patients at 13 sites were randomized to the device arm (100 patients; 369 access sites) or the MC arm (104 patients; 382 access sites). Baseline characteristics were similar between groups. Mean TTA, TPPT, TTDe, and TTH were substantially lower in the device arm (respective decreases of 54%, 54%, 52%, and 55%; all p < 0.0001). Opioid use was reduced by 58% (p ¼ 0.001). There were no major access site complications. Incidence of minor complications was 1.0% for the device arm and 2.4% for the MC arm (p ¼ 0.45). Patient satisfaction scores with duration of and comfort during bedrest were 63% and 36% higher in device group (both p < 0.0001). Satisfaction with bedrest pain was 25% higher (p ¼ 0.001) for the device overall, and 40% higher (p ¼ 0.002) for patients with a previous ablation. CONCLUSIONS Use of the closure device for multiple access ablation procedures resulted in significant reductions in TTA, TPPT, TTH, TTDe, and opioid use, with increased patient satisfaction and no increase in complications. (A Randomized, Multi-center Trial to Compare Cardiva Mid-Bore VVCS to Manual Compression in Closure of Multiple Femoral Venous Access Sites in 6 - 12 Fr Sheath Sizes [AMBULATE]; NCT03193021)
Read MoreCare Pathways/CDS: Clinical Pathway for Suspected AF
Read MoreCare Pathways/CDS: SOP for therapy options when treating AFib. Includes flow chart, decision trees, chart for AAD dosage, and risk factors/comorbidities.
Read More